AWS SAA Practice: Design Resilient Architectures

SAA-C0312 questions~6 min26% of the exam

Original scenario questions on multi-AZ and multi-region design, backups and disaster recovery, decoupling with queues, and fault-tolerant storage for the SAA-C03 exam.

Start quizFree · no account needed
SourceAWS Certified Solutions Architect — Associate
Blueprint
Domain 2 of 4
Weight
26% of SAA-C03
Questions
12 original
AWS pass
720 / 1,000
Written for QuizGen, never copied from the real exam.SAA-C03 exam guidePDF, opens d1.awsstatic.com in a new tab
All SAA-C03 domains4 drills, 12 questions each. Your readiness score then weights them 30/26/24/20, the way the SAA-C03 guide does.

One question, worked through

This is question 12 of the 12 below, solved in the open — deliberately, so you can judge the questions before you play. The other 11 stay hidden until you answer them, then reveal the same explanation.

Worked example

A rarely used internal reporting app must be recoverable within 24 hours after a regional disaster, and leadership wants the lowest possible standby cost. Which DR approach is most appropriate?

  • ABackup and restore from cross-region snapshotsCorrect
  • BActive-active across two regions
  • CWarm standby in a second region
  • DPilot light with a running database replica

Why A

With a generous 24-hour RTO and cost as the priority, backup-and-restore keeps almost nothing running in the second region and simply rebuilds from replicated snapshots. Warm standby, pilot light, and active-active all keep resources running, raising cost needlessly.

Our blueprint tag — not a source

SAA-C03 · Domain 2 of 4 · Design Resilient Architectures

We wrote this question and filed it under that domain. The domain name and its position in the outline come from the SAA-C03 exam guide (PDF, opens d1.awsstatic.com in a new tab).

Play the full quiz

All 12 questions — including the one worked through above — in about 6 minutes. Instant feedback after every answer, and your score stays on this device.

1 / 12
Practice

Question 1

An e-commerce site runs on a single RDS MySQL instance. During maintenance and hardware failures the database becomes unavailable. They need automatic failover with minimal downtime and no app changes. What should they enable?

Tap an answer, or press its letter

After this drill

How ready are you for AWS SAA?

Your attempts across all 4 drills roll up into one blueprint-weighted score, built only from the questions you actually answered. Free, and it stays on this device.

Check your readiness